LIFEGAIN CU-HD1 Defibrillator / Monitor

LIFEGAIN CU-HD1 Defibrillator / Monitor
Product Detailed
portable defibrillator monitor LIFEGAIN CU-HD1 Defibrillator / Monitor

portable defibrillator monitor LIFEGAIN CU-HD1 Defibrillator / Monitor

Product overview:

LifeGain CU-HD1 - this is the company's high end defibrillator/monitor intended for hospital use. It has defibrillation capabilities in AED and manual modes and may use disposable electrode pads and external and internal paddles for shock delivery. It has a transcutaneous pacer for temporary pacing of patients with low heart rate. It has an SPO2 module for the monitoring of oxygen saturation in the patient's blood and a 12-lead ECG monitor for the evaluation and monitoring of the patient's ECG.It has a memory card port for the storage of acquired signals and an integrated printer for the generation of hard copies of the patient's physiological signals. These features make this defibrillator suitable for use inside a hospital. This product is a defibrillator designed for qualified emergency staff and medical professionals to deliver defibrillating shocks to victims of sudden cardiac arrest and restore the normal ECG rhythm.

AED Mode

AED Mode is delivered to patients who are exhibiting the symptoms of Sudden Cardiac Arrest (SCA) including ventricular fibrillation, ventricular tachycardia, in order to bring them back to life by delivering electric shock and restoring the normal ECG rhythm.In the AED mode, defibrillation pads must be used. These defibrillation pads work to obtain the ECG signal of patients and deliver electric shock according to the patients' condition.

 Manual Mode

Manual Mode is divided into two functions such as asynchronous defibrillation and synchronous cardioversion. In asynchronous defibrillation, the usage target is the same in AED Mode. For the asynchronous defibrillation treatment in the manual mode, the user is able to choose the level of electric shock energy from the range of 1-200 joule by the use of pads or paddles. On the other side, when used for synchronous cardioversion, it is used on patients with the symptoms of atrial fibrillation. It is designed to analyze the R-wave of ECG QRS and deliver R-wave synchronized electric shocks. In the Manual mode, synchronous cardioversion treatment can be delivered to patients with rapid atrial fibrillation, ventricular tachycardia, and cardiac ischemia.

Pacer Mode

Pacing is a method applied to patients who had lost natural cardiac movement functions, mostly used on patients with bradycardia. LiFEGAIN CU-HD1 functions to support non-invasive pacing, a way of helping maintain a patient's pulse by attaching its electrode to the patient's skin and delivering artificial electric stimulation to the heart. Pacing mode is divided into the 'Fixed mode' and the 'Demand mode'.

Monitoring Mode

Patient monitoring mode features the ECG monitoring function and the function to measure the level of SpO2, functional oxygen saturation in the blood. For the ECG monitoring function, you can selectively use the 3-lead, 5-lead, 12-lead ECG cables. During the patient monitoring session, it is possible to analyze the ECG results to use the alarming function according to the conditions such as the number of pulses, ventricular fibrillation or ventricular tachycardia etc. If using an ECG cable, convert "Rotary Switch" to "Monitor mode" before usage.

Key features:

Manual and AED Operation

 Defibrillation using paddles or pads

 Synchronized cardioversion

 Efficient and effective e-cube Biphasic technology (BTE Type)

 SpO2 pulse oximetry with alarm

 ECG monitoring (3 Lead ECG / 5 Lead ECG / 10 Lead ECG)

 Noninvasive pacing mode Noninvasive Blood Pressure (NIBP)

Product specification:

You can check it in the PDF specification sheet.

Display

LCD Dimension

7 inch Diagonal (152mm * 91mm)

Type

TFT Color

Resolution

800 * 480 pixels

Defibrillation

Defib Common

Waveform

Truncated Exponential Biphasic (e~cube)

Charge Time

Adapter : Less than 5 seconds to 200Joules

Battery : Less than 7 seconds to 200Joules

AED Mode

Output Energy

200J

Shock Delivery

Via multifunction defib electrode pads

AED Develop Guideline

Shock advisory sensitivity and Specificity meet AAMI DF-80 guidelines

Voice & Text Prompt

Guide the user through the protocol via

multifunction defib electrode pads

Manual Mode

Output Energy(Selected)

1~10J, 15J, 20J, 30J, 40J, 50J, 100J, 120J, 150J, 170J, 200J

Shock Delivery

External Paddle (with Pediatric) / Internal Paddle

Synchronous Cardioversion

Printer

Continuous ECG Strip

Real-Time (8 seconds delay)

Auto Printing

Recorder can be configured to print marked event, charge, shock

And alarms

Printing Speed

25mm/s

Paper

50mm Width / 40mm Diameters

Automatic Self-Test

Power on Self-TestRun Time Self-TestManual Self-TestPeriodic Self-Test(Daily/Weekly/Monthly)

Power Source

External Battery Pack : Lithium Polymer

Type

14.8V 3.1Ah (Rechargeable)

Capacity

When new, minimum of 100shock deliveries(200J)

AC Power Pack

Output

18V, 6A

Noninvasive Pacing

Waveform

Monophasic Truncated Exponential

Mode

Demand and Fixed Mode

Amplitude Accuracy

0 ~ 200mA (5mA)

Pulse Width

20ms(1.5%)

Pulse Rate

30 ~ 180ppm (1.5%)

Refractory Period

340 msec (30 to 80 ppm)

240 msec (90 to 180 ppm)

SpO2 Pulse Oximetry

Saturation

70 ~ 100%(3digits)

Pulse Rate

20 ~ 250bpm(3bpm)

Perfusion

0.2%

Module Manufacturer

Nellcor

SpO2 Alarm

Less than Minimum setting rate

Over than Maximum setting rate

Data Storage

External memory card

SD Card(ECG data, Evend, Voice)

ECG Monitoring

Input

3-Lead Cable : I, II, III

5-Lead Cable : I, II, III, aVR, aVL, aVF or V

10-Lead Cable : I, II, III, aVR, aVL, aVF or V1, V2, V3, V4, V5, V6

(Display View:All 12-Lead ECG waves display simultaneously)

Lead Fault

“Lead Fault” messege and dashed line display,

If an electrode or lead wire becomes disconnected

Heart Rate Display

30 to 300 bpm (3bpm)

ECG Size

5, 10, 20mm/mV and Auto-gain

Heart Rate/Arrhythmia Alarm

HR, Asystole, VF, VT

Accessories:

Standard Package

- Device

- External Paddle (Reusable) - Pediatric included Power cord

- 3-Lead ECG Cable

- ECG Electrodes (15EA)

- Disposable Defi Pads & Adapter for Defi pads

- Built in Printer

- Power Cord & SMPS (Switching Mode Power Supply)

- Internal Battery (Lithium Polymer)

- Gel

- User Guide

Optional Accessories

- Carrying Case

- SD Card / SD Card Reader

- Pediatric Defi Pads (Disposable)

- 5-Lead ECG Cable (Button Type)

- ECG Electrodes (50EA)

- Printer Paper (10 rolls)

- Cigar Lighter Jack for Car

- Bed Hanger

- SpO2 Module Set (MP100, Finger Probe, Exention Cable)

- Pacer

- 10 Lead ECG Cable

- Noinvasive Blood Pressure (NIBP)

Pictures:

LIFEGAIN CU-HD1 Defibrillator / Monitor



Copyright Notice @ 2008-2022 ECBAY Limited and/or its subsidiaries and licensors. All rights reserved.