iPAD NF1200 (Semi & Fully Available) Intelligent Public Access Defibrillator
Semi-Automatical External DefibrillatoriPAD NF1200 (Semi & Fully Available) Intelligent Public Access Defibrillator
Product overview:
The i-PAD NF1200 is a semi-automated external defibrillator (also known as an AED). The i-PAD NF1200 is designed for minimally trained individuals. It provides simple and direct voice prompts and instructions for straightforward rescue operation. It is lightweight and battery powered for maximum portability. The i-PAD NF1200 is intended to treat Ventricular Fibrillation (VF) and Fast Ventricular Tachycardia. These two conditions are the most common causes of sudden cardiac arrest (SCA). In SCA, the heart of the victim suddenly stops pumping. This condition may occur suddenly to any age group without warning. The only effective treatment for SCA is the application of a defibrillating shock. |
How to use i-PAD NF1200 |
Key features:
Product specification:
You can check it in the PDF specification sheet.
Physical | ||
Size | 2.75 in high X 8.66 in wide X 10.23 in deep (70mm high X 220 mm wide X 260 mm deep) | |
Weight | Approximately 4.84 lbs (2.2 kg) with battery pack installed | |
Environmental | ||
Operating Conditions | Temperature | 32 F to110 F(0C to 43 C) |
Humidity | 5 % to 95 % (non-condensing) | |
Storage Conditions | Temperature | 32F to 110 F (0 C to 43 C) |
Humidity | 5 % to 95 % (non-condensing) | |
Shock/Drop/Abuse Tolerance | Meets IEC 60601-1 clause 21 (Mechanical Strength) | |
Vibration | Meets EN1789 random and swept sine, road ambulance specification in operating and standby states. | |
Sealing | IEC 60529: IP54 | |
ESD | Meets IEC 61000-4-2:2001 | |
EMI (Radiated) | Meets IEC 60601-1-2 limits, method EN 55011:1998+ A1:1999 +A2:2002, Group 1, Class B | |
EMI (Immunity) | Meets IEC 60601-1-2 limits, method EN 61000-4-3: 2001 Level 3 (10V/m 80MHz to 2500MHz) | |
Defibrillator | ||
Operating Mode | Semi-automated | |
Waveform | e-cube biphasic (Truncated exponential type); impedance compensated | |
Energy | 200 Joules nominal into a 50 load | |
Shock Energy Accuracy | Within ±3% (150J into 50) | |
Charge Control | Automatic by Software (Arrhythmia Detection System and Charging Control) | |
Charge time from “Shock Advised” | < 14 seconds, typical | |
Shock to Shock cycle time | < 15 seconds, typical, including analysis | |
Charge complete indicator | * Text prompt (PRESS THE FLASHING ORANGE BUTTON, NOW)* flashing backlight of SHOCK button* beep from the beeper | |
Disarm | Once charged, the NF1200 disarms if:* Patient’s heart rhythm changes to non-shockable rhythm, or* The SHOCK button is not pressed within 15 seconds after the NF1200 is armed, or* The ON/OFF button is pressed to turn OFF the NF1200, or* The defibrillator pads are removed from the patient or the pads connector is disconnected from the NF1200 | |
Defibrillator, continued | ||
Shock Delivery | Shock is delivered if the SHOCK button is pressed while the NF1200 is armed. | |
Shock Delivery Vector | Via adult defibrillator pads in the anterior-anterior (Lead II) position or via Reduced-energy pediatric pads in the anterior-posterior position. | |
Patient Isolation | Type BF | |
ECG Acquisition | ||
Acquired ECG Lead | Lead II | |
Frequency Response | 1 Hz to 30 Hz EMS Mode0.3 Hz to 40 Hz Monitoring Mode | |
ECG Analysis System | ||
Function | Determines the impedance of the patient and evaluates the ECG of the patient to determine whether it is shockable or non shockable | |
Impedance Range | 25 to 175 | |
Shockable Rhythms | Ventricular Fibrillation or Fast Ventricular Tachycardia | |
Non Shockable Rhythms | ECG rhythms other than Ventricular Fibrillation or Fast Ventricular Tachycardia | |
Sensitivity & Specificity: | Meets AAMI DF39 guidelines | |
Controls, Indicators, and Prompts | ||
Controls | Power On/Off Button, i-Button, Shock Button | |
Indicators | State LED, Graphical Rescue Guide LED | |
Audio Speaker | Provides voice prompts | |
Beeper | Provides various audible indications | |
Low Battery Detection | Automatic during daily testing and Power ON and runtime testing | |
Low Battery Indicator | State LED and Voice Prompt | |
Prompts | Voice prompts guide the user throughout a rescue operation | |
Self-Tests | ||
Automatic | * Power On Self-Test / Run Time Self-Test* daily / weekly/ monthly | |
User Initiated | Battery Insertion Test | |
Battery Pack | ||
Battery Type | 12 Volt DC, 4.2 Ah, lithium manganese dioxide, disposable long-life primary cell. | |
Capacity | Minimum 200 shocks or 4 hours of operating time. | |
Temperature Range | -40 °F to 140 °F (-40 °C to 60 °C) | |
Defibrillator Pads (CUA0512F) | ||
Type | self-adhesive, disposable, non-polarized defibrillation pads | |
Adult Pads | Defibrillation pads for patients 8 years of age and older or 55 lbs. (25 kg) and over. | |
Surface Area | Adult : 110cm2 each | |
Cable Length | 1.5m | |
Data Recording and Transmission | ||
Infrared | Wireless transmission of event data to PC through IrDA port. | |
Data Stored | First 40 minutes of ECG and the entire incident’s events and analysis decisions. |
Accessories:
Standard Package
- Device
- Disposable Defi pads
- Li-ion disposable battery
- User guide
- Quick reference card
Optional Accessories
- Carrying case
- Adaptor for battery charging
- Rechargeable Battery Pack
- IrDA Connector for data communication
- Software for data managing with Key File
- Wall Bracket
- Wall Cabinet (Small) with Alarm (Included AED Sign)
- Pediatric pads