BTI-030 (0.3T) Permanent Open MRI System
BTI-030 (0.3T) Permanent Open MRI System
Excellent price performance ratioComprehensive application suite and powerful software included in standard configuration
Patient friendly appearance Most open C-shaped magnet
Minimal sitting requirements Less than 30 m2 (325 sq.ft)
Low operating Costs Permanent magnet – no helium
Higher revenues Attractive to more patients and referring physicians
Excellent Return On-Investment Decreased costs-optimized profitability
Efficient and Professional service team 24 hours service hot-line
Specifications of BTI-030 System
1.0 Magnet:
Operating Field Strength 0.30 Tesla (3000 Gauss)Magnet Type Full open C-shape, eddy current free, self-temperature controlMagnetic material Permanent Nd-Fe-B magnet Homogeneity (400mm DSV) ≤ 2.5ppm (Vrms)Shimming Passive & active shimmingPatient gap 400mmDimension 1760cmx1200cmx1530cmNet Weight 12,000KGS
2.0 Gradient System:
Gradient strengh max. 18mT/m (Gx/Gy/Gz)Slew rate 60mT/M/ms (Gx/Gy/Gz)Gradient linearity < 5%(400mm×400mm×380mm)
3.0 RF System:
Frequency range DC~32MHzSpectrometer Digital (Single channel)Transmitting coil Flat planar coilReceiving coils Quadrature coil(Neck coil, Head coil, Large body coil, Small body coil, Knee coil)Optional coils spine coil, breast coil, ankle coil, etc.Max. receiver bandwidth 1.25MhzPower of transmitter amplifier 5KW
4.0 Computer System:
Operating system Windows2000/NT/XPCPU ≥2.8GHz(Dual Core Processor)Hard disk ≥160GBRAM 1024MB (1GB)Display Device ≥20’’ TFTNetwork & laser printer interface DICOM3.0Software BASDA BTI-030 Software
5.0 Auto Pre- scan
6.0 Pulse Sequence:
Standard IR Spin Echo ( SE 2D/3D)Multi-slice multi-echo (MSME)Gradient Echo (GRE 2D/3D)Steady state process gradient echo( SSPGRE)Fast spin echo (FSE)Single shot fast spin echo(SSFSE)Multi shot fast spin echo (MSFSE)Inversion recovery (IR)Inversion recovery fast spin echo (IRFSE)Short time inversion recovery (STIR)Fluid attenuated inversion recovery ( FLAIR)MRM ,MRU ,MRCP TOF 2D/3D MRADiffusion weighted imaging (DWI)Echo planar imaging(EPI)
7.0 Image:
Acquisition matrix 64/128/256/512Resolution 1mm(head 24cm FOV 256X256) 1.5MM(body 30cm FOV 256X256) 0.5mm(head 24cm FOV 512X512) 0.75mm( body 30cm FOV 512X512)Maximum display matrix 1024x1024FOV 20 ~ 400mmSlice thickness (2D/3D)Min.1mm(1mm increment) Slice Orientation Sagittal, coronal, transversal, any angle any obliqueImage Type T1 Weighted imaging , T2 weighted imaging ,T2* weighted imaging , proton density imaging;Water Suppressed Imange,Fat Suppressed Image, MRM, MRU,MRCP; Magnetic Resonance angiography (MRA), Diffusion Weighted Imaging (DWI)
8.0 Patient Table System:
Max. Patient load about 220kg;Available with laser light localizer for patient positioningIntercommunication between patient and operator: available
9.0 Power Supply
3N~380/400V 50/60Hz 10KVA 10.0 Typical Layout:
Magnet Room About 30m2(5m×6m);Equipment Room About 18m2(6m×3m);Control Room About 15m2(5m×3m);Total MRI-System area About 63m2.
BTI-030 (0.3T) Permanent Open MRI System